The formation of local concentrations of moisture under the applied coating that is revealed as a form of fine bubbles on the surface of the top coating.


Causes Prevention
insufficiently cleaned surface, thoroughly clean the surface before applying coat,
wet sanding of polyester materials, polyester materials should be dry sanded only,
water in the installation of compressed air, apply appropriate filters to stop moisture in the compressed air installation,
too thin coat thickness leading to increased permeability of moisture. observe recommended thickness of coating.

Repair

  • Sand and apply coat again.

Blistering
  • Blistering
  • Blistering
SCROLL TO TOP